Electronic Overcurrent Relay RMT-101

Electronic Overcurrent Relay RMT-101

Product Details:

 
Voltage Type AC
Voltage (V) 220 - 240V
Number of Poles 2 Pole
Current Range (Amps) 0 - 100A
Brand NOVATEK ELECTRO
Application Over Current Protection with Digital Ammeter function
Contact Form Potential Free, SPDT
Coil Type Latching
Current (Amp) 8A
Relay Type Current Overload Relay

RMT-101 current overload/over current relay is used for load rejection in case the current exceeds the set value between 0 and 100 amperes (settable).

The device can be used in the following capacities :

  • Digital ammeter
  • Current consumption limiting relay
  • Priority load selection relay

LEDs on the front panel of the relay indicate :

  • Load state (on/off)
  • Exceeding the maximum allowed load current threshold

Depending on the work mode, the three digit seven-segment indicator indicates:

  • Actual load current value
  • Maximum current value after the last reset
  • Value of the parameter being set
  • Time remaining until load activation or rejection
  • Presence of a reclosing blockage

Regulating potentiometers allow the user to set the following values:

  • Maximum allowed load current value threshold
  • Time for load rejection in case of exceeding
  • Maximum allowed load current threshold
  • Time delay before load activation after the current returns to the allowed level

Additional Information:

  • Item Code: RMT-101
  • Port of Dispatch: New Delhi, India

General Information:

Item

Unit

Value

Purpose of device

-

Control and distribution equipment.

Typical operation

 

Continued

Protection degree:        - device

                                      - terminal block

-

IP40

IP10

Index protection of electrical shock

-

II

Permissible degree of pollution

-

II

Overvoltage category

-

II

Nominal voltage of insulation

V

450

Rated impulse withstand voltage,

kV

2.5

 

Technical Specification:

Operation supply voltage, V

230/240

Power frequency , Hz

47 - 53

Harmonical configuration (nonsinusoidality) of power supply voltage

EN 50160:2010

Current measurement range, А

0-100

Measurement inaccuracy, no worse than

1%

Adjustment range

а) k=1; Imax, А

    absolute measurement accuracy of current, A, no more than

б) k=10; Imax, A

    absolute measurement accuracy of current, A, no more than

 

0 - 10

±0,1

0-99,9

±1

Adjustment range of ton, sec

0 - 900,

Adjustment range of toff, sec

0 - 300

Readiness time, sec, no more than *

0.8

Commutation overcurrent of the output contacts,  А, not less

8

Minimum voltage when safe operating (effective value), V **

130

Maximal voltage when safe operating (effective value), V

300

Maximum allowable start voltage, V,  no more than

400

Torque for terminal screws, N*m

0.4

Commutation life of the output contacts:

- under 8A power load, times, no less then

- under 1A power load, times, no less then

 

100 000

1 000 000

Weight , kg, no more than

0.200

Outer dimensions, 3 S-modules for 35mm DIN-rail

See fig.1                                                  

Mounting to standard 35 mm DIN-rail

Positioning

Free

* Reaction time when giving power is no more 2 seconds (autocalibration, loading and current inclusion and loading shutdown in case of emergency definition)

* Indicator switching-off is provided at supply voltage decrease more low 130 volt and blocking of functioning RМТ-101 at a supply voltage reduction more low 110 volt.

 

RMT-101 complies with requirements:

IEC 60947-1;  IEC 60947-6-2; IEC 61000-4-2; CISPR 11:2004, IDT