Electronic Overcurrent Relay RMT-101
Product Details:
Voltage Type | AC |
Voltage (V) | 220 - 240V |
Number of Poles | 2 Pole |
Current Range (Amps) | 0 - 100A |
Brand | NOVATEK ELECTRO |
Application | Over Current Protection with Digital Ammeter function |
Contact Form | Potential Free, SPDT |
Coil Type | Latching |
Current (Amp) | 8A |
Relay Type | Current Overload Relay |
RMT-101 current overload/over current relay is used for load rejection in case the current exceeds the set value between 0 and 100 amperes (settable).
The device can be used in the following capacities :
- Digital ammeter
- Current consumption limiting relay
- Priority load selection relay
LEDs on the front panel of the relay indicate :
- Load state (on/off)
- Exceeding the maximum allowed load current threshold
Depending on the work mode, the three digit seven-segment indicator indicates:
- Actual load current value
- Maximum current value after the last reset
- Value of the parameter being set
- Time remaining until load activation or rejection
- Presence of a reclosing blockage
Regulating potentiometers allow the user to set the following values:
- Maximum allowed load current value threshold
- Time for load rejection in case of exceeding
- Maximum allowed load current threshold
- Time delay before load activation after the current returns to the allowed level
Additional Information:
- Item Code: RMT-101
- Port of Dispatch: New Delhi, India
General Information:
Item |
Unit |
Value |
Purpose of device |
- |
Control and distribution equipment. |
Typical operation |
|
Continued |
Protection degree: - device - terminal block |
- |
IP40 IP10 |
Index protection of electrical shock |
- |
II |
Permissible degree of pollution |
- |
II |
Overvoltage category |
- |
II |
Nominal voltage of insulation |
V |
450 |
Rated impulse withstand voltage, |
kV |
2.5 |
Technical Specification:
Operation supply voltage, V |
230/240 |
Power frequency , Hz |
47 - 53 |
Harmonical configuration (nonsinusoidality) of power supply voltage |
EN 50160:2010 |
Current measurement range, Ð |
0-100 |
Measurement inaccuracy, no worse than |
1% |
Adjustment range а) k=1; Imax, Рabsolute measurement accuracy of current, A, no more than б) k=10; Imax, A absolute measurement accuracy of current, A, no more than |
0 - 10 ±0,1 0-99,9 ±1 |
Adjustment range of ton, sec |
0 - 900, ∞ |
Adjustment range of toff, sec |
0 - 300 |
Readiness time, sec, no more than * |
0.8 |
Commutation overcurrent of the output contacts, Ð, not less |
8 |
Minimum voltage when safe operating (effective value), V ** |
130 |
Maximal voltage when safe operating (effective value), V |
300 |
Maximum allowable start voltage, V, no more than |
400 |
Torque for terminal screws, N*m |
0.4 |
Commutation life of the output contacts: - under 8A power load, times, no less then - under 1A power load, times, no less then |
100 000 1 000 000 |
Weight , kg, no more than |
0.200 |
Outer dimensions, 3 S-modules for 35mm DIN-rail |
See fig.1 |
Mounting to standard 35 mm DIN-rail |
|
Positioning |
Free |
* Reaction time when giving power is no more 2 seconds (autocalibration, loading and current inclusion and loading shutdown in case of emergency definition) * Indicator switching-off is provided at supply voltage decrease more low 130 volt and blocking of functioning RМТ-101 at a supply voltage reduction more low 110 volt. |
RMT-101 complies with requirements:
IEC 60947-1; IEC 60947-6-2; IEC 61000-4-2; CISPR 11:2004, IDT