Intelligent Refrigerator Temperature Controller MCK-301-8X
Product Details:
Brand | NOVATEK ELECTRO |
Type | Microcontroller based intelligent logic |
Model No | MCK-301-8X |
Voltage | 220V - 415V AC |
Controller Type | Digital |
Input Sensor | PTC, NTC |
MCK 301-83 medium and deep refrigerating unit controller with automatic thawing is used to control freezer units, refrigerated counters, monoblocks and other commercial and industrial refrigerating devices.
The unit automatically maintains the freezer and evaporator temperatures as well as, depending on the mode of operation, either the second evaporator temperature or the temperature in the fan’s air flow.
If necessary, MCK-301-83 allows discovering and responding to the following emergencies:
- Short circuit or sensor breakout
- Leaving the unit door open for a longer time than allowed
- Unacceptable deviation in voltage parameters
- Sticking/welding of contactor output contacts
- Unacceptable over range of the compressor temperature
Type: Digital
Output: 8A @ 250 V AC
Temperature Range: -45 to +50 deg C
Brand: NOVATEK-ELECTRO
Model Number: MCK-301
Additional Information:
- Item Code: MCK-301
- Port of Dispatch: New Delhi, India
Technical specifications:
Name |
Value |
Nominal supply voltage: one-phase voltage is or three-phase voltage is |
230V/50Hz 400V/50Hz; |
Operating voltage: |
from 160V to 330V; |
Harmonical configuration (nonsinusoidality) of power supply voltage |
EN 61000-3-2 |
Trip threshold accuracy for voltage, V, is no more than |
3 |
Temperature resolution, °C; |
0.1 |
Power consumption, W, is no more than |
5 |
Enclosure |
IP40 |
Terminal block enclosure |
IP20 |
Climatic design version |
NС3.1 |
Permissible contamination level |
II |
Overvoltage category |
II |
Rated voltage of insulation, V |
450 |
Rated impulse withstand voltage, kV |
2.5 |
Conductor cross-section for connecting to terminals, mm² |
0.5 – 2.5 |
Tightening torque of the terminal screws, N*m |
0.4 |
Weight, kg, is no more than |
0.3 |
Mounted on the standard 35 mm DIN-rail |
|
Analog inputs: there are 3 inputs for NTC/PTC temperature sensors (temperature sensors of chamber) |
|
A digital input can be used: - to connect a door alarm sensor; - to control defrost (the decision is made according to «closed/open» state); - as an input for external alarm signal. |
|
Main outputs: -two-way break-before make relay output for the compressor control - 8A 250V at cos φ =1; -a normally open relay output for the evaporator fan control - 8A 250V at cos φ =1; -a normally open relay output for the electric heater control - 8A 250V at cos φ =1; -an opto-triac output to start an alarm signalling - 60 mA 50Hz |
|
Mounting position is arbitrary. |